+86-028-85255257
產(chǎn)品特點(diǎn)
產(chǎn)品應(yīng)用
操作極限參數(shù)
參數(shù) |
符號(hào) |
最小值 |
典型值 |
最大值 |
單位 |
存儲(chǔ)溫度 |
TS |
-55 |
100 |
°C |
|
供電電壓 |
VCC |
-0.5 |
3.6 |
V |
|
工作濕度 |
- |
95 |
% |
注:如果操作過(guò)程超過(guò)上述值,可能會(huì)對(duì)模塊造成無(wú)法恢復(fù)的損壞
正常工作參數(shù)
參數(shù) |
符號(hào) |
最小值 |
典型值 |
最大值 |
單位 |
工作溫度 |
TS |
-40 |
85 |
°C |
|
供電電壓 |
VCC |
3.13 |
3.3 |
3.465 |
V |
工作速率 |
50 |
100 |
155 |
Mbps |
光口參數(shù)
參數(shù) |
符號(hào) |
最小值 |
典型值 |
最大值 |
單位 |
速率 |
100/155 |
Mbps |
|||
發(fā)送端 |
|||||
平均輸出光功率 |
P0 |
-15 |
-8 |
dBm |
|
波長(zhǎng) |
λ C |
1260 |
1310 |
1360 |
nm |
光譜寬度(RMS) |
?λ |
4 |
nm |
||
消光比 |
ER |
8.2 |
dB |
||
上升/下降時(shí)間(20%~80%) |
tr/tf |
2 |
ns |
||
接收端 |
|||||
接收波長(zhǎng) |
λ C |
1260 |
1600 |
nm |
|
接收靈敏度 |
Pmin |
-28 |
dBm |
||
過(guò)載光功率 |
Pmax |
-3 |
dBm |
||
接收信號(hào)插入告警 |
LOSA |
-45 |
dBm |
||
接收信號(hào)檢解除告警 |
LOSD |
-29 |
dBm |
||
光回?fù)軗p耗 |
ORL |
-12 |
dB |
注:VCCTX=3.3V,工作溫度TA=全溫范圍
管腳號(hào) |
符號(hào) |
描述 |
GP |
GP |
接地管腳,連接到機(jī)殼地 |
1 |
TD+ |
發(fā)射端數(shù)據(jù)輸入正 |
2 |
VEETX |
發(fā)射信號(hào)地 |
3 |
TD- |
發(fā)射端數(shù)據(jù)輸入負(fù) |
4 |
VCCTX |
發(fā)射端電源 |
6 |
內(nèi)部4.7K電阻上拉,默認(rèn)禁止光輸出。 |
|
7 |
RD+ |
接收數(shù)據(jù)輸出正 |
8 |
VCCRX |
接收端電源 |
9 |
RD- |
接收數(shù)據(jù)輸出負(fù) |
10 |
VEERX |
接收信號(hào)地 |
注:TDIS信號(hào)為高電平有效,若不使用TX_DISABLE功能,應(yīng)將TDIS引腳下 拉至地,保持該引腳為低電平,不可懸浮,否則會(huì)導(dǎo)致模塊工作不正常。
F-tone Networks optic transceiver is designed to be Class I Laser safety compliant and is certified per the following standards
Feature |
Agency |
Standard |
Laser Safety |
FDA |
CDRH 21 CFR 1040 annd Laser Notice No. 50 |
Product Safety |
BST |
EN 60825-1:2007 EN 60825-2:2004 EN 60950-1:2006 |
Environmental protection |
SGS |
RoHS Directive 2002/95/EC |
EMC |
CCIC |
EN 55022:2006+A1:2007 EN 55024:1998+A1:2001+A2:2003 |
Part Number |
Product Description |
|||
FTRJ-1303 -10 |
50~155M, |
1310nm |
雙纖 |
LC接口, 0oC ~ +70oC |
FTRJ-1303 -10I |
50~155M, |
1310nm |
雙纖 |
LC接口, -40oC ~ +85oC |
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.